2456840000 ACT20P-UI-2RCO-DC-P
Brand: Weidmüller
Code: 2456840000
Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 24 V DC power supply
| Version | Limit value monitoring, Input : universal U, I, R,ϑ, Output : 2 x relays, Input: temperature, R, U, I, Relay output, 24 V DC power supply |
| Order No. | 2456840000 |
| Type | ACT20P-UI-2RCO-DC-P |
| GTIN (EAN) | 4050118471779 |
| Qty. | 1 items |
| 113.6 mm | |
| Depth (inches) | 4.472 inch |
| Height | 127.1 mm |
| Height (inches) | 5.004 inch |
| Width | 22.5 mm |
| Width (inches) | 0.886 inch |
| Net weight | 228 g |
| Storage temperature | -20 °C...70 °C |
| Operating temperature | -20 °C...65 °C |
| Humidity at operating temperature | 0...95 % (no condensation) |
| Humidity | 10…90 %, no condensation |
| SIL in compliance with IEC 61508 | None |
| MTBF | 180 a |
| REACH SVHC | Lead 7439-92-1 |
| SCIP | 2f6dd957-421a-46db-a0c2-cf1609156924 |
| Cable-length compensation | <±0.002 Ω per cable resistance Ω |
| Influence of the sensor cable resistance | 5 Ω @ RTD- Kabel |
| Input current | configurable ± 25 mA DC ±5 A DC |
| Input resistance, current | 40 Ω |
| Input resistance, voltage | 2 MΩ > 10 MΩ |
| Input voltage | configurable ±150 mV DC ± 600mV DC ±30 V DC ±300 V DC |
| Number of inputs | 1 |
| Potentiometer | 1.2…500 kΩ |
| Resistance | 0…10 kΩ 0…12 kΩ 0…15 kΩ |
| Sensor | Thermocouples: B, E, J, K, L, N, R, S, T, U RTD: PT100, PT200, PT1000, Ni120, Cu10, 2-/3-/4-wire |
| Sensor supply | 0.1 mA / 0.05 mA (depending on measuring range) @ RTD cable 24 V (@ 4-20 mA loop) |
| Temperature input range | B: +100…+1820 °C E: -270…+1000 °C J: (-210…+1200 °C) K: -270…+1372 °C L: +100…+900 °C N: (-180…+1300 °C) R: -50…+1768 °C S: -50…+1768 °C T: -270…+400 °C U: -200…+600 °C |
| Alarm function | configurable Top and bottom limit values, window range Alarm delay: 0…99 s Hysteresis adjustable auto / manual reset |
| Max. switching frequency | 20 Hz |
| Max. switching voltage, AC | 250 V |
| Max. switching voltage, DC | 110 V |
| Number of digital outputs | 2 |
| Rated switching current | 200mA @ 110Vdc 6A @ 24Vdc / 240Vac |
| Type | 2 CO contacts normal / inverse adjustment Switching frequency 20 Hz |
| Accuracy | <0.1 % of measuring range |
| Cold-junction compensation error | ±2.0°C @ -20° C - 70°C |
| Configuration | With FDT/DTM software or via 7-segment display, push-buttons and rotary encoder on the device itself Requires configuration adapter 8978580000 CBX200 USB |
| Galvanic isolation | 4-way isolator; Input to supply ⁄ Alarm 1 ⁄ Alarm 2 yes |
| Long-term drift | 0.1 % / 10.000 h |
| Power consumption | ≤ 3.5 W <2 W |
| Rail | TS 35 |
| Repeat accuracy | ± 0.05 % of measuring range final value |
| Step response time | 450 ms |
| Temperature coefficient | <0.02 °C of measuring range / °C 350 ppm/K |
| Voltage supply | 9...60 V DC |
| EMC standards | EN 61326-1 |
| Galvanic isolation | 4-way isolator; Input to supply ⁄ Alarm 1 ⁄ Alarm 2 yes |
| Impulse withstand voltage | 4 kV (1.2/50 µs) |
| Insulation voltage | 4 kV (input / output) |
| Pollution severity | 2 |
| Rated voltage | 300 Veff |
| Surge voltage category | III |
| Test voltage | 0.3 kV |
| Type of connection | PUSH IN |
| Tightening torque, min. | 0.4 Nm |
| Tightening torque, max. | 0.6 Nm |
| Clamping range, rated connection | 2.5 mm² |
| Clamping range, min. | 0.5 mm² |
| Clamping range, max. | 2.5 mm² |
| Wire connection cross section AWG, min. | AWG 26 |
| Wire connection cross section AWG, max. | AWG 14 |
| Wire cross-section, solid, min. | 0.2 mm² |
| Wire cross-section, solid, max. | 2.5 mm² |
| Wire connection cross section, finely stranded, min. | 0.2 mm² |
| Wire connection cross section, finely stranded, max. | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min. | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max. | 2.5 mm² |
| Product information | The devices of the ACT20P-UI-2RCO-XX-x family record current, voltage, potentiometer and temperature sensor signals (mA, A, mV, V, potentiometer, RTD and TC). They have two independent relay outputs which emit an alarm when levels exceed or fall below pre-set limits. Properties
|
| Approval/Certificate/Document of Conformity | [Declaration of Conformity](https://mdcop.weidmueller.com/mediadelivery/asset/900_37674) |
| Engineering Data | [CAD data -- STEP](https://mdcop.weidmueller.com/mediadelivery/asset/900_191120) |
| CADENAS eCATALOG | [CAX data](https://weidmueller-embedded.partcommunity.com?catalog=weidmueller_qs&part=2456840000) |
| Software | [WI-Manager, DTM-Library for online installation](https://mdcop.weidmueller.com/mediadelivery/asset/900_35364) [Release notes for Weidmueller FDT-DTM Software version](https://mdcop.weidmueller.com/mediadelivery/asset/900_248446) |
| User Documentation | [Device description -- Instruction sheet](https://mdcop.weidmueller.com/mediadelivery/asset/900_45612) [20210120 Security Advisory - WI-Manager affected by MundM Software fdtCONTAINER vulnerability](https://mdcop.weidmueller.com/mediadelivery/asset/900_189001) |
| Catalogues | [Catalogues in PDF-format](LINK/Catalog.html) |
| ETIM 6.0 | EC002654 |
| ETIM 7.0 | EC002654 |
| ETIM 8.0 | EC002654 |
| ETIM 9.0 | EC002654 |
| ECLASS 9.0 | 27-21-01-22 |
| ECLASS 9.1 | 27-21-01-22 |
| ECLASS 10.0 | 27-21-01-22 |
| ECLASS 11.0 | 27-21-01-22 |
| ECLASS 12.0 | 27-21-01-22 |
| ECLASS 13.0 | 27-21-01-22 |
| Approvals |  |
| Approvals | CULUS; |
| ROHS | Conform |
Check out any spare parts and components from the Weidmüller catalog!