2737500000 PVN1M1I6S0F3V0O1TXPX10
| Version | Photovoltaics, Combiner Box, 1000 V, 1 MPP, 6 Inputs / 6 Outputs per MPP, With fuse holder, Surge protection II, Switch disconnector, WM4C |
| Order No. | 2737500000 |
| Type | PVN1M1I6S0F3V0O1TXPX10 |
| GTIN (EAN) | 4050118824834 |
| Qty. | 1 items |
| Delivery status | This article will no longer be available in the future. |
| Available until | 31.12.2024 |
| Alternative product | [2737480000](~/p/2737480000) |
| 249 mm | |
| Depth (inches) | 9.803 inch |
| Height | 334 mm |
| Height (inches) | 13.15 inch |
| Width | 488 mm |
| Width (inches) | 19.213 inch |
| Net weight | 6,453 g |
| Ambient temperature | -25 °C...+40 °C |
| Humidity | 5 - 90 %, no condensation |
| Monitoring function | Non monitored |
| Approvals | EN 61439-2 IEC 61439-2 |
| Time interval | 5 years |
| Current per Maximum Power Point, max. | 90 A |
| Rated DC current per connection |
|
| Rated short-term current resistance |
|
| Rated DC voltage | 1,000 V |
| Switching disconnector capacity | DC-PV1 IEC 60947-3 |
| Connection type string | Plug WM4C |
| Enclosure attachment | Via mounting foots |
| Impact resistance | IK08 in accordance with IEC 62208 IK10 in accordance with IEC 62262 |
| Insulating material | Polyester glass-fibre reinforced, Polycarbonate |
| Switch disconnector execution | switch in cover |
| Type of mounting | Wall mounting 4 screws |
| Installation location | Protected outdoor area (Land and Sea) |
| Protection degree | IP65 |
| Amount of maximum power points | 1 MPP |
| Cartridge fuse | 10 x 38 mm |
| DC Input + & - |
|
| Functional earth connector |
|
| Fuse type | Empty fuse holder |
| Fuse-link standard | IEC 60269-1 IEC 60269-6 gPV (EN 60269-6) |
| Max. number of DC inputs | per Maximum Power Point 6 inputs connected in parallel |
| Surge protection auxiliary contact |
|
| DC Output + & - |
|
| Max. number of DC outputs | per Maximum Power Point 7 outputs connected in parallel |
| Discharge current In (8/20 µs) | 20 kA |
| Discharge current, max. (8/20 µs) | 40 kA |
| Maximum continuous operating voltage DC UCPV mode +/-, -/PE, +/PE | 1,100 V |
| Protection level Up (+/-) | ≤ 3.8 kV |
| Protection level Up (+/PE) | ≤ 3.8 kV |
| Protection level Up (-/PE) | ≤ 3.8 kV |
| PV system voltage, max. Ucpv | 1,100 V |
| Requirements class | Type II |
| Short-circuit curent ISCPV | 11,000 A |
| Standby power consumption PC | < 0.2 W |
| Total discharge current Itotal ( 8/20µs) | 50 kA |
| Product information | Fuses are not included |
| Approval/Certificate/Document of Conformity | [EU Declaration of Conformity](https://mdcop.weidmueller.com/mediadelivery/asset/900_185178) |
| Engineering Data | [CAD data -- PV Next Schematic Diagram 6In6Out](https://mdcop.weidmueller.com/mediadelivery/asset/900_187727) [CAD data -- STEP](https://mdcop.weidmueller.com/mediadelivery/asset/900_304962) |
| Technical Documentation | [Customer Drawing](https://mdcop.weidmueller.com/mediadelivery/asset/900_185000) |
| User Documentation | [Manual PV Next String Combiner Box](https://mdcop.weidmueller.com/mediadelivery/asset/900_96571) [MANUAL PV NEXT IT/ES/FR](https://mdcop.weidmueller.com/mediadelivery/asset/900_153695) |
| White paper | [Fact Sheet DE PV CB Wie man Gebäude gegen Blitzeinschläge schützt](https://mdcop.weidmueller.com/mediadelivery/asset/900_249825) [Fact Sheet DE PV Wie man die Lebensdauer eines GAK verlängert](https://mdcop.weidmueller.com/mediadelivery/asset/900_249826) [Fact Sheet DE PV CB Richtig verbinden](https://mdcop.weidmueller.com/mediadelivery/asset/900_290542) [Fact-Sheet EN PV CB Load break switch](https://mdcop.weidmueller.com/mediadelivery/asset/900_290549) [Fact Sheet EN CB Combining PV strings](https://mdcop.weidmueller.com/mediadelivery/asset/900_290550) [Fact Sheet EN PV CB connection](https://mdcop.weidmueller.com/mediadelivery/asset/900_290551) [Fact Sheet EN PV Combiner Box earthing](https://mdcop.weidmueller.com/mediadelivery/asset/900_303983) [Fact Sheet DE PV Combiner Box Erdung](https://mdcop.weidmueller.com/mediadelivery/asset/900_303984) [Fact Sheet DE PV CB Wann Sicherungen zu installieren sind](https://mdcop.weidmueller.com/mediadelivery/asset/900_249827) [Fact Sheet DE CB PV NEXT](https://mdcop.weidmueller.com/mediadelivery/asset/900_249828) [Fact Sheet EN PV CB When DC fuses are mandatory to install](https://mdcop.weidmueller.com/mediadelivery/asset/900_249829) [Fact Sheet EN CB PV NEXT](https://mdcop.weidmueller.com/mediadelivery/asset/900_249830) [Fact Sheet EN PV How to protect buildings against lightning strikes](https://mdcop.weidmueller.com/mediadelivery/asset/900_249831) [Fact Sheet EN PV How to extend the life time of a Combiner Box](https://mdcop.weidmueller.com/mediadelivery/asset/900_249832) [Fact Sheet DE PV CB Lastentrennschalter](https://mdcop.weidmueller.com/mediadelivery/asset/900_290540) [Fact Sheet DE CB PV Strings kombinieren](https://mdcop.weidmueller.com/mediadelivery/asset/900_290541) |
| Catalogues | [Catalogues in PDF-format](LINK/Catalog.html) |
| ETIM 6.0 | EC002928 |
| ETIM 7.0 | EC002928 |
| ETIM 8.0 | EC003857 |
| ETIM 9.0 | EC003857 |
| ECLASS 9.0 | 22-57-92-03 |
| ECLASS 9.1 | 22-57-02-90 |
| ECLASS 10.0 | 22-57-02-90 |
| ECLASS 11.0 | 22-57-02-92 |
| ECLASS 12.0 | 22-57-02-92 |
| ECLASS 13.0 | 22-57-02-92 |
| Long specification | Combiner box for inverters with 1 MPP tracker, suitable for protecting the DC side of a photovoltaic system according to EN 51543-32. MPP1: Max. string voltage Uoc: 1000V Approval according to low voltage switchgear and controlgear IEC 61439-1:2011 and EN 61439-2:2011 |
| Approvals |  |
Check out any spare parts and components from the Weidmüller catalog!
Do you want to order a 2737500000 PVN1M1I6S0F3V0O1TXPX10 with code: 2737500000?