2743460000 FP PRO TOP3 24/20 2PIOL
Brand: Weidmüller
Code: 2743460000
FieldPower® power supply unit, IP65, in closed state, in complete state, 20A, 24 V, DC, IDC terminal, PUSH IN, M12 A-coded (IO-Link)
| Version | FieldPower® power supply unit, IP65, in closed state, in complete state, 20A, 24 V, DC, IDC terminal, PUSH IN, M12 A-coded (IO-Link) |
| Order No. | 2743460000 |
| Type | FP PRO TOP3 24/20 2PIOL |
| GTIN (EAN) | 4050118892130 |
| Qty. | 1 items |
| 220 mm | |
| Depth (inches) | 8.661 inch |
| Height | 196 mm |
| Height (inches) | 7.717 inch |
| Width | 196 mm |
| Width (inches) | 7.717 inch |
| Net weight | 4,256 g |
| Storage temperature | -10 °C...60 °C |
| Operating temperature | -25 °C...45 °C |
| Operating temperature range | -25 °C... +45 °C (regard derating) Start up ≥ -40 °C |
| Humidity | 35…85%, non condensing and non freezing |
| REACH SVHC | Lead 7439-92-1 Potassium perfluorobutane sulfonate 29420-49-3 |
| SCIP | 7645f3b1-6db9-495d-9e21-ab1d894aff05 |
| AC current consumption | 1,5 A @ 400 V DC / 2 A @ 320 V AC |
| AC input voltage range | 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC |
| Connection system | IDC terminal |
| DC input voltage range | 450...800 V DC (max. 500 V DC acc. to UL508) |
| Frequency range AC | 45…65 Hz |
| Input fuse (internal) | 5 A F (6.3 x 32 mm) |
| Inrush current | Max. 10 A |
| Recommended back-up fuse | 3 - 5 A, Char C |
| Surge protection | Varistor |
| Wire connection method | IDC terminal PUSH IN |
| Adjustable rated current | No |
| Nominal output current for Unom | 20 A @ 60 °C |
| Output current | 20A |
| Output power | 480 W |
| Output voltage | 24 V |
| Output voltage type | DC |
| Output voltage, max. | 28.8 V |
| Output voltage, min. | 22.5 V |
| Output voltage, note | (adjustable via potentiometer) |
| Rated output voltage | 24 V DC ± 1 % |
| Surge protection | Varistor |
| Switch-on delay | 1 s |
| Triggering characteristic | see characteristic curve |
| Wire connection method | IDC terminal PUSH IN |
| Humidity | 35…85%, non condensing and non freezing |
| Installation advice | Lid screws included |
| Protection degree | IP65 in closed state in complete state |
| Short-circuit protection | Yes internal |
| Standards | UL 508 |
| Surge voltage category | III II |
| Surge voltage category | III II |
| Connection system | IDC terminal |
| Certificate no. (cULus) | E258476 |
| Institute (cULus) | CULUS |
| AC current consumption | 1,5 A @ 400 V DC / 2 A @ 320 V AC |
| AC input voltage range | 3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC |
| DC input voltage range | 450...800 V DC (max. 500 V DC acc. to UL508) |
| Frequency range AC | 45…65 Hz |
| Recommended back-up fuse | 3 - 5 A, Char C |
| Surge protection | Varistor |
| Inrush current | Max. 10 A |
| Input fuse (internal) | 5 A F (6.3 x 32 mm) |
| Adjustable rated current | No |
| Output current | 20A |
| Output power | 480 W |
| Output voltage | 24 V |
| Output voltage type | DC |
| Output voltage, max. | 28.8 V |
| Output voltage, min. | 22.5 V |
| Output voltage, note | (adjustable via potentiometer) |
| Switch-on delay | 1 s |
| Triggering characteristic | see characteristic curve |
| Rated output voltage | 24 V DC ± 1 % |
| Nominal output current for Unom | 20 A @ 60 °C |
| Connection data - contact element power bus |
|
| Connection data - contact element Branch / Feed-in |
|
| Rated data acc. to IEC for contact element |
|
| Rated data acc. to IEC for fuse plug |
|
| Rated data acc. to IEC for plug-in connector |
|
| Rated data acc. to UL for contact element |
|
| Rated data acc. to UL for fuse plug |
|