Datasheet excerpt: Technical data of IC-KP2-2HB6-V15B
| Product Description |
|---|
| Control interface unit IDENTControl Compact with interface for PROFIBUS DP |
| General specifications | ||
|---|---|---|
| Number of read/write heads | max. 2 alternatively 1 read/write head and 1 trigger sensor | |
| UL File Number | E87056 | |
| Indicators/operating means | ||
| LED BUS | green: Slave is at state "Data Exchange" red: Bus error | |
| LED Diag | No function | |
| LEDs 1, 2 | Status indicator for read/write heads green: command at read/write head active yellow: approx. 1 second long, if command was successfully executed | |
| LEDs CH1, CH2 | green: read head detected red: Configuration error | |
| LED PWR/ERR | green: power on red: Hardware fault | |
| Rotary switch | Address setting 00... 7E, FF (hexadecimal) BUS Address (high nibble): 0... 7, F BUS Address (low nibble): 0... F | |
| Electrical specifications | ||
| Rated operating voltage | 20... 30 V DC , PELV | |
| Ripple | ≤ 10 % at 30 V DC | |
| Current consumption | ≤ 4 A incl. read/write heads | |
| Power consumption | 2 W Without read/write heads | |
| Galvanic isolation | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff | |
| Interface 1 | ||
| Interface type | PROFIBUS | |
| Physical | RS-485 | |
| Protocol | PROFIBUS DP acc. to EN 50170 | |
| Transfer rate | 9.6; 19.2; 93.75; 187.5; 500; 1500 kBit/s 3; 6; 12 Mbit/s self-synchronizing | |
| Interface 2 | ||
| Interface type | Diagnostic Interface | |
| Physical | RS 232 | |
| Protocol | ASCII | |
| Transfer rate | 38.4 kBit/s | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61000-6-2 EN 61000-6-4 | |
| RoHS | ||
| Directive 2011/65/EU (RoHS) | IEC/EN 63000 | |
| Standard conformity | ||
| Degree of protection | IEC 60529 | |
| Ambient conditions | ||
| Ambient temperature | -25... 70 °C (-13... 158 °F) | |
| Storage temperature | -40... 85 °C (-40... 185 °F) | |
| Climatic conditions | air humidity max. 96 % Salt spray resistant to EN 60068-2-52 | |
| Shock and impact resistance | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 | |
| Mechanical specifications | ||
| Housing length | 137 mm | |
| Housing width | 62 mm | |
| Housing height | 42 mm | |
| Degree of protection | IP67 | |
| Connection | Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M4 earthing screw Diagnostic RS 232: M12 connector PROFIBUS: M12 connector, B-coded | |
| Material | ||
| Housing | powder coated aluminum | |
| Installation | screw fixing | |
| Mass | approx. 300 g | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 13.0 | 27280401 |
| ECLASS 12.0 | 27280401 |
| ECLASS 11.0 | 27280401 |
| ECLASS 10.0.1 | 27280401 |
| ECLASS 9.0 | 27280401 |
| ECLASS 8.0 | 27280401 |
| ECLASS 5.1 | 27280401 |
| ETIM 9.0 | EC002998 |
| ETIM 8.0 | EC002998 |
| ETIM 7.0 | EC002998 |
| ETIM 6.0 | EC002998 |
| ETIM 5.0 | EC002998 |
| UNSPSC 12.1 | 43211710 |