Timer, Counter KC-LCD-48-1R-230VAC

Timer, Counter KC-LCD-48-1R-230VAC

Code: KC-LCD-48-1R-230VAC

Counter/Timer, Adding/subtracting via 2 separate inputs, Batch controller with 1 pre-selection, Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output status, Display range and preselection range from -999999 up to 999999
Overflow will be evaluated correctly up to 1 decade

Datasheet excerpt: Technical data of  KC-LCD-48-1R-230VAC

Product Description
LCD batch controller with 1 relay output and 230 VAC supply voltage
General specifications
Pre-selectionsingle
Data storage> 10 years, EEPROM
Programmingkeypad-driven menu
Indicators/operating means
Type2-line, 2 x 6-digit LC display with leading sign
Display valuedigit height 9 mm
Pre-selectiondigit height 7 mm
Key interlockvia "high" potential at "LOCK" input
Decimal point0 to max 5 fractional digits
Scale factor0.0001... 99.9999
Resetmanually or external
Electrical specifications
FusingT 0.1 A
Operating voltage230 V AC
Power consumptionmax. 6.5 VA
Input
ConnectionCounter inputs: A and B
Control/reset inputs: LOCK, RESET
Signal voltage
High3.5... 30 V DC
Low0... 2 V DC
Counting frequency30 Hz / 5 kHz
Minimum pulse durationControl/reset inputs: static / 1 ms
Impedance10 kOhm
Count modes
Pulse counterCounting with counting direction (cnt.dir),
difference counting (up.dn),
up/down counting (quad),
TimerTime measurement via GATE input (FrErun),
counter input A: Start, counter input B: Stop (InpA.InpB.),
counter input B: Start/Stop (InpB.InpB.),
Output
Relaychangeover contact
Switching voltagemax. 250 V AC / 110 V DC
Switching currentmax. 3 A AC/DC, min. 30 mA DC,
Switching powermax. 750 VA / 90 W
Mechanical life2 x 107 switching cycles
Electrical life5 x 104 cycles at 3 A
Response time< 15 ms pulse counter
< 10 ms time counter
Sensor supply14.4... 27.6 V DC
max. 50 mA at 230 VAC
Compliance with standards and directives
Directive conformity
Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2
EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999
Standard conformity
Emitted interferenceDIN EN 55011:2009, Class B
Mech. capacityEN 60068-2-6:2008
10 … 55 Hz / 1 mm / XYZ
30 min in each direction
Shock and impact resistanceEN 60068-2-27:1995
100 G / 2 ms / XYZ
3 times in each direction
Ambient conditions
Ambient temperature-10... 50 °C (14... 122 °F)
Storage temperature-25... 75 °C (-13... 167 °F)
Relative humidity≤ 93 % at 40 °C
(noncondensing)
Altitude0... 2000 m
Pollution degree2
Mechanical specifications
Degree of protectionIP65 (front)
Massapprox. 230 g
Dimensions48 mm x 48 mm x 109.8 mm

Classifications

SystemClasscode
ECLASS 13.027210301
ECLASS 12.027210301
ECLASS 11.027210301
ECLASS 10.0.127210301
ECLASS 9.027210301
ECLASS 8.027210301
ECLASS 5.127210301
ETIM 9.0EC002300
ETIM 8.0EC002300
ETIM 7.0EC002300
ETIM 6.0EC002300
ETIM 5.0EC000677
UNSPSC 12.141111902

Check out any spare parts and components from the Pepperl+Fuchs catalog!