Timer, Counter, Tachometer KC-LCDC-48-6T-230VAC

Timer, Counter, Tachometer KC-LCDC-48-6T-230VAC

Code: KC-LCDC-48-6T-230VAC

Counter/Timer/Tachometer, Adding/subtracting via 2 separate inputs, Batch controller with 6 pre-selections, 6 floating optocoupler outputs, Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and the status of the two outputs

Datasheet excerpt: Technical data of  KC-LCDC-48-6T-230VAC

Product Description
LCD batch controller with 6 optocoupler outputs and 90... 260 VAC supply voltage
General specifications
Pre-selection6-fold
Data storage> 10 years, EEPROM
Programmingkeypad-driven menu
Functional safety related parameters
MTTFd410 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Type2-line, 2 x 6-digit LC display with leading sign
Multicolor, backlit
Display valuedigit height 9 mm
Pre-selectiondigit height 7 mm
Key interlockvia "high" potential at "LOCK" input
Decimal point0 to max 5 fractional digits
Scale factor0.0001... 99.9999
Resetmanually or external
Electrical specifications
Fusing90 … 260 V AC: T 0.1 A
Operating voltage90... 260 V AC
Power consumptionmax. 8 VA
Input
ConnectionCounter inputs: A and B
Control/reset inputs: LOCK, RESET, GATE, MPI
Signal voltage
High12... 30 V DC
Low0... 4 V DC
Counting frequencymax. 50 kHz
Minimum pulse durationControl/reset inputs: 10 ms / 1 ms
Impedance5 kOhm
Count modes
Pulse counterCounting with counting direction (cnt.dir),
difference counting (up.dn),
up/down counting (quad),
Cumulative counting (up.up),
up/down counting x 2 (quad 2),
up/down counting x 4 (quad 4),
additional functions for counter input A and counter input B:
A/B, (A-B)/A x 100% 
Frequency counterfunctions for input A and input B:
A, A-B, A+B quad, A/B, (A-B)/A x 100 %
TimerTime measurement via GATE input (FrErun),
counter input A: Start, counter input B: Stop (InpA.InpB.),
counter input B: Start/Stop (InpB.InpB.),
time measuring via RESET input (auto)
Output
Sensor supply20.4... 27.6 V DC,
max. 80 mA
Response timeAdd/Sub/autorepeat < 6 ms
A/B; (A-B)/A: < 23 ms
Optocoupleroutput 1 to 6, NPN-Opto coupler
output 3 to 6 with common emitter
Schaltleistung 30 V DC / 10 mA
Signal voltageUCESAT with IC = 10 mA: max. 2 V
UCESAT with IC = 5 mA: max. 0.4 V
Compliance with standards and directives
Directive conformity
Low Voltage Directive 2006/95/ECEN 61010-1:2001; protection class: 2
EMC Directive 2004/108/ECEN 61000-6-2:2005, EN 50295:1999
Standard conformity
Emitted interferenceDIN EN 55011:2009, Class B
Mech. capacityEN 60068-2-6:2008
10 … 55 Hz / 1 mm / XYZ
30 min in each direction
Shock and impact resistanceEN 60068-2-27:1995
100 G / 2 ms / XYZ
3 times in each direction
Ambient conditions
Ambient temperature-20... 65 °C (-4... 149 °F)
Storage temperature-25... 75 °C (-13... 167 °F)
Relative humidity≤ 93 % at 40 °C
(noncondensing)
Altitude0... 2000 m
Pollution degree2
Mechanical specifications
Degree of protectionIP65 (front)
Massapprox. 151 g
Dimensions48 mm x 48 mm x 109.8 mm

Classifications

SystemClasscode
ECLASS 13.027210301
ECLASS 12.027210301
ECLASS 11.027210301
ECLASS 10.0.127210301
ECLASS 9.027210301
ECLASS 8.027210301
ECLASS 5.127210301
ETIM 9.0EC002300
ETIM 8.0EC002300
ETIM 7.0EC002300
ETIM 6.0EC002300
ETIM 5.0EC000677
UNSPSC 12.141111902

Check out any spare parts and components from the Pepperl+Fuchs catalog!