WIS transmitter secondary NDS5-30GM-1M-V1
Brand: Pepperl+Fuchs
Code: NDS5-30GM-1M-V1
Datasheet excerpt: Technical data of NDS5-30GM-1M-V1
| Product Description |
|---|
| Inductive transmitter system |
| General specifications | ||
|---|---|---|
| Installation | non-flush | |
| Transfer distance | 0... 5 mm | |
| Output type | 2-wire | |
| Functional safety related parameters | ||
| MTTFd | 37485 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| Ambient conditions | ||
| Ambient temperature | 0... 50 °C (32... 122 °F) | |
| Storage temperature | -25... 85 °C (-13... 185 °F) | |
| Mechanical specifications | ||
| Housing material | brass, nickel-plated | |
| Sensing face | PBT | |
| Degree of protection | IP67 | |
| Installation | screw mounting | |
| Free zone | ≥ 3 mm | |
| Spacing to metal walls | ≥ ∅ 50 mm | |
| Security zone | ≥ 60 mm x 15 mm | |
| General information | ||
| Note | Maximum cable length between WIS module and WIS transmitter must not exceed 5 m. | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 13.0 | 27274090 |
| ECLASS 12.0 | 27274090 |
| ECLASS 11.0 | 27270190 |
| ECLASS 10.0.1 | 27270190 |
| ECLASS 9.0 | 27270190 |
| ECLASS 8.0 | 27270190 |
| ECLASS 5.1 | 27270190 |
| ETIM 9.0 | EC002714 |
| ETIM 8.0 | EC002714 |
| ETIM 7.0 | EC002714 |
| ETIM 6.0 | EC002714 |
| ETIM 5.0 | EC002714 |
| UNSPSC 12.1 | 39121550 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!