Retroreflective sensor with polarization filter, Visible red light, pulsed LASER light, Ultra bright LEDs for power on, weak signal indication and switching state, Powerful push-pull output, Test input, Not sensitive to ambient light, even with switched energy saving lamps
Datasheet excerpt: Technical data of RL28-55-LAS/76a/82b/110/115
| Product Description |
|---|
| Retroreflective sensor with polarization filter |
| General specifications | ||
|---|---|---|
| Effective detection range | 0... 30 m | |
| Reflector distance | 0.3... 30 m | |
| Threshold detection range | 42 m | |
| Reference target | MH82 reflector | |
| Light source | laser diode | |
| Light type | modulated visible red light | |
| Polarization filter | yes | |
| Laser nominal ratings | ||
| Note | LASER LIGHT , DO NOT STARE INTO BEAM | |
| Laser class | 1 | |
| Wave length | 650 nm | |
| Beam divergence | < 1.5 mrad | |
| Pulse length | approx. 4.5 µs | |
| Repetition rate | approx. 6 kHz... 20 kHz | |
| max. pulse energy | 4 nJ | |
| Diameter of the light spot | approx. 45 mm at 30 m | |
| Opening angle | Emitter: < 0.1 ° Receiver: < 2 ° | |
| Ambient light limit | 50000 Lux | |
| Functional safety related parameters | ||
| MTTFd | 560 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 60 % | |
| Indicators/operating means | ||
| Operation indicator | LED green | |
| Function indicator | 2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted | |
| Control elements | sensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-on/dark-on changeover switch | |
| Electrical specifications | ||
| Operating voltage | 10... 30 V DC | |
| Ripple | max. 10 % | |
| No-load supply current | ≤ 35 mA | |
| Protection class | II, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 | |
| Input | ||
| Test input | emitter deactivation with +Ub | |
| Output | ||
| Stability alarm output | 1 PNP, inactive when falling short of the stability control for 10;s immediately inactive if 4 light beam interruptions take place | |
| Switching type | light/dark on switchable | |
| Signal output | 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected | |
| Switching voltage | max. 30 V DC | |
| Switching current | max. 100 mA | |
| Voltage drop | ≤ 2.5 V DC | |
| Switching frequency | 1000 Hz | |
| Response time | 0.5 ms | |
| Conformity | ||
| Product standard | EN 60947-5-2 | |
| Laser safety | EN 60825-1 | |
| Approvals and certificates | ||
| EAC conformity | TR CU 020/2011 | |
| Protection class | II, rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 | |
| UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
| FDA approval | IEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 | |
| Ambient conditions | ||
| Ambient temperature | -10... 50 °C (14... 122 °F) | |
| Storage temperature | -40... 60 °C (-40... 140 °F) | |
| Mechanical specifications | ||
| Housing width | 25.8 mm | |
| Housing height | 88 mm | |
| Housing depth | 54.3 mm | |
| Degree of protection | IP67 | |
| Connection | 2.5 m, 5-wire, fixed cable, Euronorm | |
| Material | ||
| Housing | Plastic ABS | |
| Optical face | Plastic pane | |
| Mass | 80 g | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 13.0 | 27270902 |
| ECLASS 12.0 | 27270902 |
| ECLASS 11.0 | 27270902 |
| ECLASS 10.0.1 | 27270902 |
| ECLASS 9.0 | 27270902 |
| ECLASS 8.0 | 27270902 |
| ECLASS 5.1 | 27270902 |
| ETIM 9.0 | EC002717 |
| ETIM 8.0 | EC002717 |
| ETIM 7.0 | EC002717 |
| ETIM 6.0 | EC002717 |
| ETIM 5.0 | EC002717 |
| UNSPSC 12.1 | 39121528 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!
Do you want to order a Retroreflective sensor RL28-55-LAS/76a/82b/110/115 with code: RL28-55-LAS/76a/82b/110/115?
Leave your request on our website for immediate assistance!