Double sheet sensor UDC-18GM50-400-3E0-610MM-6AMP

Double sheet sensor UDC-18GM50-400-3E0-610MM-6AMP

Code: UDC-18GM50-400-3E0-610MM-6AMP

Ultrasonic system for reliable detection of no, one, or two overlapping sheet materials, preferably papers, Analog current and voltage output, Short version, Sensing range: 20... 60 mm , optimal distance: 45 mm, Thread mold: M18, Construction type: Cylindrical, thread, Series: -UDB, Output type: 3 switch outputs NPN, NO, UL approval: cULus Listed, General Purpose, Class 2 Power Source, Connection type: fixed cable with plug

Datasheet excerpt: Technical data of  UDC-18GM50-400-3E0-610MM-6AMP

General specifications
Sensing range20... 60 mm , optimal distance: 45 mm
Transducer frequency395 kHz
Indicators/operating means
LED greenindication: single sheet detected
LED yellowindication: no sheet detected (Air)
LED redindication: double sheet detected
Electrical specifications
Operating voltage18... 30 V DC , ripple 10 %SS
No-load supply current< 50 mA
Time delay before availability< 500 ms
Input
Input typeFunction input
0-level: -UB... -UB + 1V
1-level: +UB - 1 V... +UB
Pulse length≥ 100 ms
Impedance≥ 4 kΩ
Output
Output type3 switch outputs NPN, NO
Rated operating current3 x 100 mA , short-circuit/overload protected
Voltage drop≤ 3 V
Switch-on delayapprox. 15 ms (shorter response time on request)
Switch-off delayapprox. 15 ms (shorter response time on request)
Pulse extensionmin. 120 ms programmable
Compliance with standards and directives
Standard conformity
StandardsEN IEC 60947-5-2:2020
IEC 60947-5-2:2019
Approvals and certificates
UL approvalcULus Listed, General Purpose, Class 2 Power Source
Ambient conditions
Ambient temperature0... 60 °C (32... 140 °F)
Storage temperature-40... 85 °C (-40... 185 °F)
Mechanical specifications
Connection typefixed cable with plug
Housing diameter18 mm
Degree of protectionIP67
Material
Housingnickel plated brass; plastic components: PBT
Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam
Connector
Number of pins6
Connection assemblyTyco connector: 103653-5
Tyco terminal: 5-104505-7
Cable
Cable diameter4.6 mm +/- 3 mm
Core cross section0.14 mm2
Length2 m
Mountingwith nuts, M18
General information
Supplementary informationSwitch settings of the external programming adapter:
"output load": pull-up
"output logic": inv

Classifications

SystemClasscode
ECLASS 13.027272801
ECLASS 12.027272801
ECLASS 11.027272801
ECLASS 10.0.127272801
ECLASS 9.027272801
ECLASS 8.027272801
ECLASS 5.127272801
ETIM 9.0EC001847
ETIM 8.0EC001847
ETIM 7.0EC001847
ETIM 6.0EC001847
ETIM 5.0EC001847
UNSPSC 12.141111960

Check out any spare parts and components from the Pepperl+Fuchs catalog!


Do you want to order a Double sheet sensor UDC-18GM50-400-3E0-610MM-6AMP with code: UDC-18GM50-400-3E0-610MM-6AMP?


Leave your request on our website for immediate assistance!

Write a review
Note: HTML is not translated!
    Bad           Good
Captcha