AS-Interface sensor/actuator module VBA-4E3A-KE-ZE/R
Brand: Pepperl+Fuchs
Code: VBA-4E3A-KE-ZE/R
KE switch cabinet module, 4 inputs (PNP) and 3 relay outputs
Datasheet excerpt: Technical data of VBA-4E3A-KE-ZE/R
| Product Description |
|---|
| KE switch cabinet module, 4 inputs (PNP) and 3 relay outputs |
| General specifications | ||
|---|---|---|
| Node type | A/B node | |
| AS-Interface specification | V2.1 | |
| Required gateway specification | ≥ V2.1 | |
| Profile | S-7.A.0 | |
| IO code | 7 | |
| ID code | A | |
| ID1 code | 7 | |
| ID2 code | 0 | |
| UL File Number | E106378 | |
| Indicators/operating means | ||
| LED FAULT | Fault display; Red LED red: Communication fault or address is 0 red, flashing: Overload, internal input supply | |
| LED INT | Internal input supply active; LED green | |
| LED PWR | AS-Interface voltage; LED green | |
| LED IN | switching state (input); 4 LED yellow | |
| LED OUT | Switching state (output); 3 LED yellow | |
| Electrical specifications | ||
| Auxiliary voltage (input) | 12... 30 V DC PELV | |
| Rated operating voltage | 26.5... 31.6 V from AS-Interface | |
| Rated operating current | ≤ 35 mA (without sensors) / max. 235 mA | |
| Surge protection | O1... O3: Over voltage category II UEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) | |
| Input | ||
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC | |
| Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) | |
| Voltage | 21... 31 V DC (INT) | |
| Current loading capacity | ≤ 150 mA, overload- and short-circuit protected (INT) | |
| Input current | ≤ 8 mA (limited internally) | |
| Switching point | according to DIN EN 61131-2 (Type 2) | |
| 0 (unattenuated) | ≤ 2 mA | |
| 1 (attenuated) | ≥ 4 mA | |
| Signal delay | < 2 ms (input/AS-Interface) | |
| Signal frequency | ≤ 250 Hz | |
| Output | ||
| Number/Type | 3 relay outputs, normally open | |
| Supply | none | |
| Nominal load | ||
| Per contact | max. 2 A / 30 V DC; 2 A / 250 V AC | |
| Per module | 6 A | |
| Minimum load | ||
| Per contact | 10 mA / 5 V DC | |
| Short-circuit-proof | Contact: 500 A / 40 ms | |
| Switching off power | 500 VA | |
| Switching delay | < 10 ms (AS-Interface/contact) | |
| Usage category | DC-13 and AC-14 | |
| Switching frequency | < 20 Hz (without load) < 0.1 Hz (nominal load) | |
| Switching | ||
| Mechanical | 30 x 106 | |
| Electrical | 1 x 106 switching cycles (40 V DC, 2 A, ohmic) 0.5 x 106 switching cycles (253 V AC, 2 A, cos φ = 1) 0.45 x 106 switching cycles (253 V AC, 2 A, cos φ = 0.7) | |
| Galvanic isolation | ||
| Input/Output | IN1... IN4 to O1... O3: safe isolation acc. to EN 60947-1, rated insulation voltage 278 V AC | |
| Input/AS-Interface | none | |
| Output/Output | O1 to O2, O3: safe isolation according to EN 60947-1, rated insulation voltage 278 V AC O2 to O3: basic insulation according to EN 60947-1, rated insulation voltage 278 V AC | |
| Output/AS-Interface | safe isolation acc. to EN 60947-1, rated insulation voltage 278 V AC | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 | |
| Low voltage | ||
| Directive 73/23/EEC | EN 60947-1:2007 | |
| Standard conformity | ||
| Galvanic isolation | EN 60947-1 | |
| Electromagnetic compatibility | NAMUR NE 21: 1998-08 | |
| Degree of protection | EN 60529:2000 | |
| Pollution degree | EN 60947-5-1 | |
| Input | EN 61131-2:2004 | |
| Usage category | EN 60947-5-1 | |
| Emitted interference | EN 61000-6-4:2007 | |
| AS-Interface | EN 62026-2:2013 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Ambient conditions | ||
| Ambient temperature | -25... 60 °C (-13... 140 °F) | |
| Storage temperature | -25... 85 °C (-13... 185 °F) | |
| Relative humidity | 85 % , noncondensing | |
| Climatic conditions | For indoor use only | |
| Altitude | ≤ 2000 m above MSL | |
| Pollution degree | 2 | |
| Mechanical specifications | ||
| Degree of protection | IP20 | |
| Connection | removable terminals rated connection capacity: rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2 for multiple-wire connection with two wires of equal cross-section: flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 | |
| Material | ||
| Housing | PA 66-FR | |
| Mass | 170 g | |
| Mounting | DIN mounting rail | |
| Tightening torque of clamping screws | 0.5 Nm... 0.6 Nm | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 13.0 | 27242604 |
| ECLASS 12.0 | 27242604 |
| ECLASS 11.0 | 27242604 |
| ECLASS 10.0.1 | 27242604 |
| ECLASS 9.0 | 27242604 |
| ECLASS 8.0 | 27242604 |
| ECLASS 5.1 | 27242604 |
| ETIM 9.0 | EC001599 |
| ETIM 8.0 | EC001599 |
| ETIM 7.0 | EC001599 |
| ETIM 6.0 | EC001599 |
| ETIM 5.0 | EC001599 |
| UNSPSC 12.1 | 39121535 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!
Do you want to order a AS-Interface sensor/actuator module VBA-4E3A-KE-ZE/R with code: VBA-4E3A-KE-ZE/R?
Leave your request on our website for immediate assistance!