Vibration sensor VIM82PP-S1V16-21E-I422C28
Brand: Pepperl+Fuchs
Code: VIM82PP-S1V16-21E-I422C28
Vibration sensor with safety function both for the analog current output and for the 2 relay outputs with adjustable swichting thresholds, Series: Performance Plus Line, Measured variable: Vibration velocity, Safety Integrity Level (SIL): SIL 2, Output type: relay, Output type: relay, Output type: analog output, current
output of the vibration variable, Equipment protection level Gb: IECEx ULD 22.0031X, Equipment protection level Db: IECEx ULD 22.0031X, Equipment protection level Gb: UL 22 ATEX 2869 X
Datasheet excerpt: Technical data of VIM82PP-S1V16-21E-I422C28
| Product Description |
|---|
| Vibration sensor with safety function both for the analog current output and for the 2 relay outputs with adjustable swichting thresholds |
| General specifications | ||
|---|---|---|
| Type | Vibration sensor | |
| Measuring technology | MEMS | |
| Series | Performance Plus Line | |
| Measured variable | Vibration velocity | |
| Measurement range | ||
| Vibration velocity | 0... 16 mm/s | |
| Measurement accuracy | ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measurement range greater than 8 mm/s | |
| Cross-sensitivity | < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis | |
| Frequency range | 10... 1000 Hz | |
| Averaging time | for v-rms: 2 s | |
| Functional safety related parameters | ||
| Safety Integrity Level (SIL) | SIL 2 | |
| Performance level (PL) | PL d | |
| Category | Cat. 2 | |
| MTTFd | 329 a | |
| Mission Time (TM) | 10 a | |
| Diagnostic Coverage (DC) | min. 90 % | |
| Indicators/operating means | ||
| Status indicator | 6 LEDs for operating states | |
| Control elements | 4 rotary switches and 1 push button for programming | |
| Electrical specifications | ||
| Fusing | external fuse is required: 3 A , semi-time-lag , 30 V DC | |
| Operating voltage | 24 V DC + 7 % / - 10 % | |
| Current consumption | max. 100 mA | |
| Power consumption | 2.6 W | |
| Time delay before availability | 15 s (initially self-test functions are executed before safe measured values are available at the output) | |
| Surge protection | up to 2 kV | |
| Output 1 | ||
| Output type | relay | |
| Switching function | Normally open (NO) | |
| Switching voltage | max. 30 V DC | |
| Switching current | max. 1 A | |
| Output 2 | ||
| Output type | relay | |
| Switching function | Normally open (NO) | |
| Switching voltage | max. 30 V DC | |
| Switching current | max. 1 A | |
| Output 3 | ||
| Output type | analog output, current output of the vibration variable | |
| Output current | 4... 20 mA | |
| Load resistor | ≤ 500 Ω | |
| Standard conformity | ||
| Degree of protection | DIN EN 60529, IP66, IP67 | |
| Shock resistance | DIN EN 60068-2-27, 60 g, 6 ms | |
| Vibration resistance | DIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz | |
| Functional safety | DIN EN IEC 61508 , SIL 2 EN ISO 13849 , PL d | |
| Approvals and certificates | ||
| IECEx approval | ||
| Equipment protection level Gb | IECEx ULD 22.0031X | |
| Equipment protection level Db | IECEx ULD 22.0031X | |
| ATEX approval | ||
| Equipment protection level Gb | UL 22 ATEX 2869 X | |
| Equipment protection level Db | UL 22 ATEX 2869 X | |
| Ambient conditions | ||
| Ambient temperature | -40... 60 °C (-40... 140 °F) | |
| Measuring head temperature | -40... 85 °C (-40... 185 °F) directly at the mounting point | |
| Storage temperature | -40... 60 °C (-40... 140 °F) | |
| Mechanical specifications | ||
| Connection type | cable | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Housing length | 77.3 mm | |
| Housing width | 62 mm | |
| Housing height | 46 mm | |
| Degree of protection | IP66 / IP67 only in connected state and correctly mounted housing cover | |
| Cable | ||
| Number of cores | 8 | |
| Length | 2 m | |
| Mass | 880 g | |
| General information | ||
| Scope of delivery | 1 x allen head screw M8 x 20 1 x spring washer M8 1 x seal label | |
| Use in the hazardous area | see instruction manuals Only use accessories specified by the manufacturer. | |
Classifications
| System | Classcode |
|---|---|
| ECLASS 13.0 | 27271103 |
| ECLASS 12.0 | 27201406 |
| ECLASS 11.0 | 27201406 |
| ECLASS 10.0.1 | 27201406 |
| ECLASS 9.0 | 27201406 |
| ECLASS 8.0 | 27201406 |
| ECLASS 5.1 | 27201406 |
| ETIM 9.0 | EC004309 |
| ETIM 8.0 | EC004309 |
| ETIM 7.0 | EC002959 |
| ETIM 6.0 | EC002959 |
| ETIM 5.0 | EC001758 |
| UNSPSC 12.1 | 41114624 |
Check out any spare parts and components from the Pepperl+Fuchs catalog!
Do you want to order a Vibration sensor VIM82PP-S1V16-21E-I422C28 with code: VIM82PP-S1V16-21E-I422C28?
Leave your request on our website for immediate assistance!